Show simple item record

dc.contributor.authorDharan, Nila J.
dc.contributor.authorAmisano, Danielle
dc.contributor.authorMboowa, Gerald
dc.contributor.authorSsengooba, Willy
dc.contributor.authorBlakemore, Robert
dc.contributor.authorKubiak, Rachel W.
dc.contributor.authorArmstrong, Derek T.
dc.contributor.authorJones, Martin
dc.contributor.authorManabe, Yukari C.
dc.contributor.authorJoloba, Moses L.
dc.contributor.authorEllner, Jerrold J.
dc.contributor.authorDorman, Susan E.
dc.contributor.authorAlland, David
dc.date.accessioned2025-05-22T08:26:35Z
dc.date.available2025-05-22T08:26:35Z
dc.date.issued2015
dc.identifier.citationDharan, N.J. et al. (2015). Improving the Sensitivity of the Xpert MTB/RIF Assay on sputum pellets by decreasing the amount of added sample reagent: a laboratory and clinical evaluation. Journal of Clinical Microbiology, 53(4), 1258-1263.en_US
dc.identifier.urihttps://journals.asm.org/doi/full/10.1128/jcm.03619-14
dc.identifier.urihttp://hdl.handle.net/10570/14551
dc.description.abstractThe Xpert MTB/RIF(Xpert) assay permits rapid near-patient detection of Mycobacterium tuberculosis in sputum; however, the test sensitivity remains suboptimal in paucibacillary specimens that are negative for acid-fast bacilli using smear microscopy. Xpert testing includes dilution with sample reagent, and when processed sputum pellets are tested, the recommended sample reagent/pellet ratio is 3:1. We evaluated whether a decreased sample reagent/pellet ratio of 2:1 increased Xpert sensitivity compared to the recommended3:1. The limit of detection was determined by inoculating serial dilutions of M. tuberculosis into sputum samples,preparing sputum pellets, and testing each pellet by Xpert at both sample reagent ratios. Processed sputum pellets obtained from M.tuberculosis culture-positive clinical specimens were also tested by Xpert at both ratios. Among spiked sputum pellets, the limit of detection was 1,478 CFU/ml (95% confidence interval [CI], 1,211 to 1,943) at a 3:1 ratio and decreased to 832 CFU/ml(95%CI,671to1,134)at2:1. The proportion of specimens in which M.tuberculosis was detected was greater at 2:1 than at 3:1 for almost all numbers of CFU/ml;this difference was most prominentat lower numbers of CFU/ml.Among134concentrated sputum pellets from the clinical study, the sensitivity of Xpert at 2:1 was greater than at 3:1 overall (80% versus 72%; P 0.03) and for smear-negative specimens (67% versus 58%; P 0.12).For Xpert testing of sputum pellets,using a lower sample reagent/pellet ratio increased M. tuberculosis detection, especially for paucibacillary specimens. Our study supports use of a 2:1 sample reagent/pellet dilution for Xpert testing of sputum pellets.en_US
dc.language.isoenen_US
dc.publisherAmerican Society for Microbiologyen_US
dc.subjectMycobacterium tuberculosisen_US
dc.subjectSputum testen_US
dc.subjectTuberculosisen_US
dc.subjectTBen_US
dc.subjectXpert MTB/RIFen_US
dc.subjectPCR-based diagnosticen_US
dc.subjectPaucibacillary specimensen_US
dc.titleImproving the Sensitivity of the Xpert MTB/RIF Assay on sputum pellets by decreasing the amount of added sample reagent: a laboratory and clinical evaluationen_US
dc.typeArticleen_US